E&I Inspector Commissioning Supervisor

  • 15+ Years Oil & Gas Experience
  • Project Management
  • Contract / Commercial
  • Electrical Engineering
  • BOSIET – Basic Offshore Safety Induction Escape Training
  • English, Tamil Speaking
Product Enquiry

Extended Profile

15+ Years Oil and Gas Experience in field engineering & constructions, site supervision, pre-commissioning & start-up activities, inspection, Ex inspection, testing & loop checks for electrical & process instrumentation, package equipment, devices, field works and engineering documentations. Familiar with International Codes & Standards for onshore & offshore construction work. Actual work done includes field engineering, design reviews, generated scope of work for contract packages, wrote QA/QC & validation procedures, project execution plan, generated system definition & handover packages, attended in tri party walk for system mechanical completion, pre-commissioning and Commissioning & start up, vendor & contractor’s coordination meetings and progress reviews. Specialties include E&I Construction Field Engineer or Supervisory, QA & QC Inspector, Ex inspection, Mechanical completion turnover Engineer & Coordinate works, who seeks to make full use of his over sixteen(17) years of professional experiences in the various fields in onshore and offshore construction works for E&I installation, project engineering, construction management & pre-commissioning & Commissioning & inspection, startup & testing works includes coordinate with contractors / subcontractors to ensure that the approved HSE, QA/QC procedures, construction execution plan & schedule are implemented.
 

 

Please follow and like us:
536

Daily Rate $400.00

The Average Day Rate payable for E&I Inspector Commissioning Supervisor is $400.00 USD per Day. A Standard Contract Working Day is classed as 10 Hours with 1 unpaid Hour for Lunch. Additional allowance is Payable depending on location, which covers, Accommodation, Transport to and from the work site and Daily Allowance for Food, Beverage and Laundry. To estimate your daily team costs select the add this expert to your team. On Completion go to My Completion Team and Complete the Short Inquiry Form and we will do the rest…

Please follow and like us:
536

EIT Room Commissioning Supervisor

EIT Room Commissioning Supervisor – Total E&P Angola Project (Block32) – Sembawang Shipyard – TOTAL E&P – Provides day to day support to Field commissioning team during energisation testing activities. Prepare all testing dossiers along with proper document to safely execute the work. (Drawings,procedures, single line diagram, schematic logic diagram, etc…) Ability to execute electrical commissioning activates and guides Technicians during execution. Ensure that all commission activities are completed in a safe, Ability to organize the team work. Perform any other related duties and responsibilities as and when directed by Supervisor. Ensures correct tool packages are available along with detailed comprehensive Commission procedures for individual job. Trouble shooting and problems resolving.
 

 

Please follow and like us:
536

EIT Field Engineer with CompEx

EIT Field Engineer with CompEx – Golar Hilli FLNG Project – Keppel Shipyard – Golar Norway – GE Gas Turbine PGT25+ G4 DLE Ce/Co 2BCL906 Heavy duty & Aero derivative. The HSPT installation activity must be supervised and or performed by Nuovo Pignone PGT25+ specialist only. To ensure the compliance of the resulting complex machine with the applicable requirements pursuant to European Community Product Directives (machinery directive, PED, ATEX, EMC and low voltage) in relation to the partly completed machinery supplied by GE Oil & Gas Nuovo Pig none. Executes the specific inspection Executes the specific inspections on materials, equipment and construction/installation activities on site. Issues the relevant Quality Records and, when necessary, writes and sends to QC Supervisor non-conformances reports. Checks cable laying and cable identification. Performs all relevant loop checks. Updates as built drawings. Performs punch-listing operations. Aero derivative gas turbine PGT25+G4 do to the inspection Seal gas panel & Synthetic oil vapour separator & Mineral oil console & Fuel gas drivers panel & Hydraulic starting skid & Seal gas heater & 2BCL 906 Centrifugal Compressor Gas Chromatograph panel & C02 Fire-Fighting Skid & Ventilation ducts. These documents are listed in SIC00123, with a cross reference on installation SQCL if CE marking is required. Mechanical Completion Construction work is complete, Include Pre-commissioning activities. General inspections for the electrical instrumentation and control sections, the tests and measurements to be carried out for low voltage (categories 0 and 1) and high-voltage systems (categories 2 and 3), and the tests and measurements for the various types of protection for potentially explosive atmospheres (Ex d, Ex e, Ex n, Ex p and Ex i). Visually make sure that internal components are not damaged. Make sure that there are no loose connections between cables, leads or relay anchorage systems both panels and of internal sub-racks.
l Make sure that the panel input leads are correctly and completely connected in accordance with the “Interconnecting Wiring diagram” SOM6765156.Check the insulation of power leads. Ex hazardous area inspection strategy development & Implementation. Executes the specific inspections on materials, equipment and construction/installation activities on site. Issues the relevant quality records and, when necessary, writes and sends to QC compiling registers and client databases.

 

 

Please follow and like us:
536

EIT Inspection with CompEx

EIT Inspection with CompEx – Teekay Fpso – Mega Shipyard – Brazil – All the modules Installation Ladder & Cable pulling & Termination & Inspection with Comp Ex done means Oil Separation Modules M08 & Utility module M12 & Main Gas Compression Modules M04 & M03 & Main Power Generation Modules M07 & M10 Main Power Generation Modules M07& M10(GE Gas Turbines 9HA.01 at 429MW and 9HA.02 at 519MW 50Hz & Liquid Gas Diyapethtion Module M05 & Gas Re-Injection ModuleM01 & Knock out drum ModuleM02 & Produced water treatment Module M09 & VRU Module M06 & Turret (One sub sea). Ensure Contractor procured items are performed and delivered as per schedule and specifications. Monitor all activities, including supply and installation, carried out by the EPCI contractor for his disciplines. Ensure timely completion of instrumentation and electrical works, safely and in compliance with specifications and regulations. Electrical Equipment’s Installation for Atmospheric Explosion Proof for Turret, Upper deck & Main deck and Modules, helideck, Cranes, Cable Termination and Completion as per the project DNV & IECEx Standards. Updates as built drawings. Performs carry over punch listing, Clear all kind of punch lists with international Standards followed instruments electrical items. Do punch listing and make comments/recommendations/request for corrective design or changes through proper channel.

 

 

Please follow and like us:
536

E&I QA/QC Inspector

E&I QA/QC Inspector – KRAKEN FPSO – Keppel Shipyard – ENQUEST – Executes the specific inspections on materials, equipment and construction/installation activities on site. Issues the relevant Quality Records and, when necessary, writes and sends to QC Supervisor non-conformances reports. Checks cable laying and cable identification. Inspection and Testing of Electrical & Instrumentation and Communication Equipment per Client and DNV requirement for FPSO Project and Specialized inspection DNV Class required. Inspects wiring of assemblies for accuracy of stripping, soldering, and crimping, and for defects, such as frayed wires, loose connections, and cracks. Checks power transformers, switchboard, accumulator battery, sockets outlet, lighting system. Performs visual inspections, dimensional test, checks rating and material for connection. Performs tests of continuity, insulation resistance. Calibrates safety valves. Calibrates instruments. Inspection of Electrical Equipment Installation for Explosion Atmosphere for Genset M70A & M70B and M25 Modules Inspection, Cable Termination and Mechanical Completion as per the ATEX & IECEx sstandards. Verifies wire and cable length, dimensions, and clearance of parts, using precision instruments. Tests continuity and performance of parts, assemblies, and accessories, using test equipment. Records acceptance or rejection of parts on inspection report, and indicates reason for rejection. Equipment is clearly marked with identification & Area Classification & Gas group and temperature class is correct or not need to be checked. Monitor all activities for installation, including supply and installation, carried out by the EPC contractor for his disciplines. Inspection of Electrical Equipments Installation for Explosion Atmosphere for Wartsilla power Gen M70A & M70B Model:34DF, Engine type 9L34DF,4320KW (V 04.-13.8kv) 50Hz Genset Atex CompEx Inspection do.

 

 

Please follow and like us:
536

Reviews

There are no reviews yet.

Be the first to review “E&I Inspector Commissioning Supervisor”

Your email address will not be published. Required fields are marked *

E&I Q/A & Q/C Inspection

E&I Q/A & Q/C Inspection – Quad204 FPSO (Glen Lyon) – Hyundai Heavy Industries – BP (British Petroleum Corporation)  – Check conformity with the Quality Control Plan, obtain the relevant documentation, check procedures and equipment to be used in tests, controls and inspections, manage documents certifying tests, controls and inspections. Ensure the correct implementation of the approved Inspection Test Plan. Inspection and Testing of Electrical & Instrumentation and Communication equipment as per deck and Modules Inspection, Cable Termination and Mechanical Completion as per the ATEX & IECEx standards. And Examine electrical systems and equipment. Monitor and sign for Electrical & Mechanical completion of ITR & ITP. And look for frayed wires and loose connections. Compile inspection reports. Raising punch list for against ITR clear the punch list. GE power generation Module: STF-A650 STEAM TURBINES Atex inspection & GE’s STF-A650 combined-cycle steam turbines 50Hz and 60Hz do Ex inspections.GE turbines Thermocouple, vibration elements, temperature elements, JB’s, transmitters, limit switches, all steam turbines do the inspections. GE power generation Module: STF-A650 Steam turbines inspection & GE’s STF-A650 combined-cycle steam turbines 50Hz and 60Hz do inspections. Monitor and Report in Project weekly meeting of status. Certified ATEX compliance after inspection carried out. Keep records and write reports. Direct coordinate Engineering, manufacturing, construction, installation, maintenance and support documentation and testing activities to ensure compliance with specifications, codes of practices and customer requirements. Updates as built drawings. Pre-commissioning and Assisting in Commissioning of Turret Instrumentation and equipment’s Performing Line check and Loop check of all the Instrument and Electrical cable prior to commissioning. Witness the tests, controls and inspections carried out. Involves in Construction Inspection and Pre-commissioning activities and review technical drawings and support with Engineering for the technical issues with site.
 

 

Please follow and like us:
536

E&I Atex Ex Inspector

E&I Atex Ex Inspector – ENSCO-5006 Semi-Submersible  – Keppel Fels – INPEX (Ichthys) Corporation – IEC 60079-0:2011 specifies the general requirements for construction, testing and marking of electrical equipment and Ex Components intended for use in explosive atmospheres. Electrical equipment complying with this standard is intended for use in hazardous areas in which explosive gas atmospheres, caused by mixtures of air and gases, vapours or mists, exist under normal atmospheric conditions. Equipment is clearly marked with Ex identification & Area Classification & Gas group and temperature class is correct or not need to be checked. Test continuity. Inspection of Electrical Equipment’s Installation for Atmospheric Explosion Proof for drill floor inspection, Cable Termination and Inspection as per the ATEX and EEHA Standards. Inspect wiring of assemblies for accuracy of stripping, soldering, and crimping, and for defects. Inspection of Electrical equipment’s Installation for Atmospheric Explosion Proof for Drill floor, upper deck and Cantilever means Iron rope neck, Top drive, Crown, Derrick & Mud pit room, Shaleshekar, Moon pool means main deck Inspections & Helifuel Area, Cable Termination and Remedial works to Completion as per the ATEX Standard and EEHA standards. Ex inspections are critical to assure the continuing integrity of the types of protection that enable Ex electrical equipment use in potentially explosive atmospheres and are carried out under the standard IEC BS EN 60079-17. Examine and inspect wire harnesses, control panels, coaxial cables, and electrical jig boards, for completeness of assembly, quality, and conformance to blueprints. We work with clients to support and provide them with a path towards full compliance under the mandatory Requirements of IEC/BS EN60079-17/14, DSEAR (Dangerous Substances in Explosive Atmospheres Regulations), The Equipment Directive ATEX 95 (94/9/EC) and the workers Directive ATEX 137 (99/92/EC).

 

 

Please follow and like us:
536

EIT Supervisor

EIT Supervisor – EKOLFISH Norwegian Accommodation Platform – Sembawang – ConocoPhillips – Electrical Systems for accessories shall be in compliance with NORSOK standards E-CR-001. Ensure sub-contractor is using the latest revised drawings and documents by performing weekly checks on their documents against the drawing/document registers. Conduct daily site inspection and surveillance to capture deficiencies in fabricated components, installed item or systems. Responsible of E&I installation & inspection activities on the Site NORSOK standards. Installation & inspection of instruments and electrical equipment’s and panels. Supervise the quality control function on the field. Ensure the correct implementation of the approved Inspection Test Plan. Conducting different tests such as line check& loop tests carried out by the Yard. Monitoring, review and inspection of all major activities of the E&I construction works. Interface with engineering, planning and procurement as well as other disciplines. Review maintenance records to highlight any problems. Conduct an ignition hazard assessment on non-electrical equipment’s. Assess the electrical equipment with respect to its certification record our findings in a report or file Implement any corrective action arising. Responsible of E&I installation & inspection activities on the Site, Installation & inspection of instruments and electrical equipment and panels.

 

 

Please follow and like us:
536

EIT (ATEX) Inspector

EIT Ex (ATEX) Inspector – FPSO (Berantai) – Keppel Shipyard – Petronas -Implementation of quality plan for this project, which include inspection, testing and proper documentation and ensure that all works complied with client issued (IFC) drawing, applicable standards and specification. Implementing coverage of proper installation, wiring and cable laying, cladding, termination, witnessing of insulation resistance test. Continuity testing, hydro-testing, loop checking and pre-commissioning of all the field instruments i.e. level flow, temperature pressure and control valves. Responsible in inspection of instrument to its conformity with the specification on the data sheets with the actual commodity. Check physical,material size, tag number, color code, model, process connection, reference drawings. Signs specification data sheets calibration sheet after thorough checking of instruments involved prior to actual installation. Specification check on instruments i.e. temperature gauges, Thermocouples pressure gauges, control valves, transmitters, manifolds etc. Writes request for inspection (RFIs). Issue NCR on instruments installed that does not conform to the standards specified by the client. Involves in Construction, Inspection and Pre-Commissioning & commissioning activities. Review technical drawings and support with Engineering for the technical issues. Attend FAT to outsource Electrical equipment’s & Instruments check all vendor instruments. Carry out the checks as required by the Inspection Test Record (ITR-A), Carry out “As–Built” Drawing on Layout Drawings and Single line drawings ensure strict implementation of Permit to Work System that remains in force throughout onshore Mechanical Completion works. Inspection of Electrical equipment’s Installation for Turret, Upper deck and Modules Inspection, engine room, Cable Termination and Mechanical Completion as per the Project Standards. Do punch listing and make comments/recommendations/request for corrective design or changes through proper channel. Compiling as-built drawings and up-dating last revision, direct modification for any changes. Prepare and issue site instruction to E&I contractors for the work modification and other scopes or not related in constructions.
 

 

Please follow and like us:
536

E&I Inspection & Commissioning

E&I Inspection & Commissioning – FPSO Bumi Armada (TGT-1) Project – Keppel Shipyard – Hoang long (petro Serve) Vietnam – Ensure that all related inspection and testing activities with regards to Environment, Health & Safety procedures and maintenance rules are respected. Monitor the performance of construction to ensure the respect of work standards and project specifications. Perform proactive surveillance inspection to minimize or avoid discrepancy and non-conformance rectification cost and time. Coordinate and assist construction to resolve any encountered problems related to inspection and testing activities to meet schedule and avoid any delay of activities. IEC 60079-0:2011 specifies the general requirements for construction, testing and marking of electrical equipment and Ex Components intended for use in explosive atmospheres. Electrical equipment complying with this standard is intended for use in hazardous areas in which explosive gas atmospheres, caused by mixtures of air and gases, vapours or mists, exist under normal atmospheric conditions. enure strict implementation of Permit to Work (PTW) System that remains in force throughout onshore Mechanical Completion. Performs pre-commissioning such as Insulation test and Resistance test in all Electrical-motors. Pre-commissioning and Assisting in Commissioning of Instrumentation and Equipments. Performing Line check and Loop check of all the Instrument and Electrical cable prior to commissioning. Involves in Construction Inspection and Commissioning activities. Review technical drawings and support with Engineering for the technical issues. attend FAT& SIT test to outsource Electrical & Instruments equipments.

 

 

Please follow and like us:
536

EIT Commissioning Supervisor

EIT Commissioning Supervisor – FPSO MAERSK PEREGRINO – Keppel Shipyard -Statoil – Installation & inspection of instruments and electrical equipment and panels. Supervise the quality control function onsite Inspection of Instrument Installation, loop check, simulation & functional testing of all the process instruments. Mechanical completion for HVAC system, Inspection of instrument and electrical equipment such as Air Controlled Dampers, Temperature sensors, Air flow sensors, Pre-commissioning works, loop checking, Megger testing. pre-commissioning group, testing of each instrument loop of the DCS, calibration of pressure transmitter, temperature transmitter, all kind of valves & transmitters. Function testing of every transmitter such as pressure transmitter using available air supply or air pump, calibration of and function testing of temperature transmitter using decade box, Fluke temp injector, thermal bath, Calibration and function testing of flow transmitter using HART Communicator Injecting 4ma to 20ma or as per design specification. l Assist the vendor in commissioning various fire and gas devices control interfacing DCS systems. Performs Mechanical Completion, Inspections of installed electrical and instrument equipment as per client’s specification and design. Documentation completion, and MC check sheet turn overs. punch list generation and rectification as required or back job to constructions. Review construction documentation prior to executing commissioning activities. Complete the project Completion System in accordance with project completion procedures. Ensure all activities are carried out in a safe manner and in accordance with the project PTW systems.

 

 

Please follow and like us:
536

E&I Mechanical Completion Supervisor

E&I Mechanical Completion Supervisor – MAERSK (OLIE OG GAS AS)
HALFDAN B PHASE IV DEVELOPMENT-Platform Project – SMOE Shipyard – Electrical systems for accessories shall be in compliance with NORSOK Standards E-CR-001. Create preparing inspection/test report on prescribed format and maintaining proper filling system including the final documentation at the end of the projects. Monitors all activities through the quality control to ensure compliance to quality assurance requirement throughout the various stages in the project. Quality Check the all Instruments as per the Spec drawings. Attend weekly production meeting to discuss production progress and problem encountered during inspection time and make corrective measurement & correct action. Provide technical query for approval of changes in drawings. Prepare all documentation for Equipments material list and prepare the Inspection test report ITR after successfully completed the Inspections. System overview and arrangement of final documentation of the projects. Performs mechanical completion punch listing, clear all kind of Instruments & electrical items. Monitors all activities through the quality control to ensure compliance to quality assurance requirement throughout the various stages in the projects.

 

 

Please follow and like us:
536

E&I Completion Supervisor

E&I Completion Supervisor – -13 (West Orion) Semi-Submersible Rig – Jurong Shipyard – Petrobras – Monitoring and updating the calibration of all E&I testing equipment’s. Organize the preparation of Electrical energization and Instrument Loop Packages. Conduct monitoring inspections for conformance to project P&ID’s, IFC drawings and specifications for the Electrical, Instrumentation and Controls work carried out by Contractor and Subcontractor internal QC efforts. Monitor fabrication and installation activities, inclusive of process review / compliance, confirmation of company approved procedures, calibration of equipment per procedure or specifications, review of documented reports and related safety measures are implemented and are effective. Check and Monitor of Mechanical and Electrical completion and Test report (ITRs) submit to the document control departments or PIMS. Coordinates with the discipline engineers, and company representatives prior to inspection as per I.T.P. Reports Site Manager and Lead QA/QC weekly and monthly surveillance visits to Contractor and their suppliers and subcontractors. Support during integration of topside module, turret, loading arm, and vessel for all ongoing job in electrical, instrumentation, fire and gas, telecommunication. Submit daily/weekly/monthly reports to Site Quality Assurance and Inspection Lead and maintain detailed written reports. To monitor changes, ensuring that all scope of changes is quickly and properly documented and Changes are approved prior to the performance of works.

 

 

Please follow and like us:
536

E&I Commissioning Senior Technician

E&I Commissioning Senior Technician – FSO QUEENSWAY – Jurong Shipyard – Tanker Pacific Offshore Terminal – Responsible of Project management team activities of all Electrical & Instrumentation(E&I). construction work in the project, ensuring that it is carried out in according with AFC drawing. Specifications Class Rules, Regulations and the approved project ITP. Coordinate electrical & instrument scope in terms of administration of agreed deliverable, work orders and communication with all relevant parties. Liaise between shipyard and company (E&I engineering & commissioning team) and class ABS as required. Provide coverage for Electrical and Instrumentation inspection duties when required or as directed by QA/AC Supervisor and E&I engineers. Check and Monitor of Mechanical and Electrical completion and Test report. To ensure the E&I work is done in compliance with applicable rules and standards including ABS rules with Company and shipyard Standards with project Safety policies and procedures. To monitor the weekly work schedules and expeditious progress in E&I tasks recognizing the critical path of the master schedule. Support planning and execution of Pre-commissioning and commissioning works. To monitor changes, ensuring that all scope of changes is quickly and properly documented and changes are approved prior to the performance of works. Assist contractor to ensure understanding/ interpreting of job requirements, be pro-active and guide, whenever needed to minimize reworks.

 

 

Please follow and like us:
536

E&I Inspector

E&I Inspector – MODEC (CIDADE DO RIO DE JANEIRO) FPSO-MV14 – Jurong Shipyard  – PETROBRAS. Brazil – Perform motor insulation resistance test, loop checking, perform no-load and load run test of motor, set as per load requirement test. Perform in energization of the medium voltage and low voltage panel, MV transformer and dry type LV distribution transformers. To review technical drawings and support with Engineering for the technical issues. Check with Hazardous Area Classification, Explosion Proof Requirements. Performed E&I Inspections as per the project scope and class requirements. Carried out Commissioning of 11KV Distribution system, Distribution transformer system, Fire detection system, PA/GA system, Telephone System, Lighting system, 480V switch board, and UPS System etc. Supervise, job Scheduling and work Allocation. Skills in solving technical issues. Installation, testing and commissioning of 11KV, 690V, 480V Switchboards. Installation, Testing Commissioning and Operation of HV/LV Generators and transformers. Carried out HI-POT test in various Projects. 30 KV Switch Gear Apply voltage 56kv ac (duration1min) IEC 60298, 60694. And 5.5kv Switch Gear Apply voltage 16kv Ac, duration 1min reference code and standard IEC 60298, 60694.

 

 

Please follow and like us:
536

E&I Project Supervisor

E&I Project Supervisor – MODEC FPSO (COMPANION FPSO & PRA-1 FSO) Projects. PETROBRAS (P-43) (P-50) (P-54) FPSO Projects – GLOBAL SANTA FE-1&2 (Semi-Submersible rigs) – Jurong Shipyard (A group of SembCorp marine) Singapore – Petrobras, Modec. Responsible of E&I installation & inspection activities on the Site. Installation & inspection of instruments and electrical equipment and panels. Inspect Electrical & Instrumental Work carried out by the shipyards. Conducting different tests such as line check& loop tests carried out by the shipyards. Monitoring, review and inspection of all major activities and progress of the E&I construction works Interface with engineering, planning and procurement as well as other disciplines. As a project supervisor to carried out Installation of electrical equipment and instruments. Such as switchboards, lighting panels, small power distribution panels installations. Carried out hot work, Cable ladder, Cable pulling, termination segregation of cable dressing. Power systems (LV/MV) Performs (cause and Effect) testing for Fire & gas and HVAC Systems. Public addresses and General alarm systems, lighting systems, Pre-commissioning . Process stations for thrusters, Emergency shut down system, and tank gauging system, termination cable line to line checking, cable Megger 500v-inject and checking. Fire and Gas Systems Prepare ITR report and submit to the document control means QA/QC. Navigational and Radio Systems. CCTV and Entertainment systems installed the panels.

 

 

Please follow and like us:
536